PRODUCT
FEATURES
• 100% unbalanced output, each phase; Max. output up to 50% rated power
• Up to 2 MPPTs, Max. charging/discharging current up to 240A
• Max. 6 pcs parallel
• 6 time periods for battery charging/discharging
• On-grid and off-grid operation; Support multiple batteries in parallel
• AC couple to retrofit existing solar system
• IP65 protection grade
• Support storing energy from diesel generator
Model | PD0080G-TPM-EU | PD0100G-TPM-EU | PD0120G-TPM-EU |
Battery Input Data | |||
Battery Type | Lead-acid or Lithium-ion | ||
Battery Voltage Range (V) | 40-60V | ||
Max. Charging Current (A) | 190A | 210A | 240A |
Max. Discharging Current (A) | 190A | 210A | 240A |
Charging Strategy for Li-ion Battery | Self-adaption to BMS | ||
Number of Battery Input | 1 | ||
PV String Input Data | |||
Max. PV Input Power (W) | 10400W | 13000W | 15600W |
Max. PV Input Voltage (V) | 800V | ||
Start-up Voltage (V) | 160V | ||
MPPT Voltage Range (V) | 200-650V | ||
Rated PV Input Voltage (V) | 550V | ||
Full Load DC Voltage Range | 350-650V | ||
Max. Operating PV Input Current (A) | 13A + 13A | 26A + 13A | |
Max. Input Short-Circuit Current (A) | 17A + 17A | 34A + 17A | |
No. of MPPT | 2 | ||
No. of Strings per MPPT | 1+1 | 2+2 | |
AC Input/Output Data | |||
Rated AC Input/Output Active Power (W) | 8000 | 10000 | 12000 |
Max. AC Input/Output Apparent Power (VA) | 8800 | 11000 | 13200 |
Peak Power(off-grid) | 2 times of rated power, 10s | ||
Rated AC Input/Output Current (A) | 12.16/11.6 | 15.21/14.5 | 18.25/17.4 |
Max. AC Input/Output Current (A) | 13.38/12.8 | 16.73/15.9 | 20.07/19.1 |
Max. Three-phase Unbalanced Output Current (A) | 18.18//17.4 | 22.72/21.7 | 27.27/26.1 |
Max. Continuous AC Passthrough (grid to load) (A) | 45 | ||
Max. Output Short Circuit Current (A) | 75 | ||
Peak Power (off-grid) (W) | 2 times of rated power, 10s | ||
Power Factor Adjustment Range | 0.8 leading to 0.8 lagging | ||
Output Frequency and Voltage | 50/60Hz; 3L+N+PE, 220/380V, 230/400V (three phase) | ||
Grid Type | Three Phase | ||
Total Current Harmonic Distortion THDi | <3% (of nominal power) | ||
DC Injection Current | <0.5% In | ||
Efficiency | |||
Max. Efficiency | 97.6% | ||
Euro Efficiency | 96.5% | ||
MPPT Efficiency | >99% | ||
Equipment Protection | |||
Integrated | PV Arc Fault Detection, PV Input Lightning Protection, Anti-islanding Protection, PV String Input Reverse Polarity Protection, Insulation Resistor Detection, Residual Current Monitoring Unit, Output Over Current Protection, Output Shorted Protection | ||
Surge Protection Level | TYPE II(DC), TYPE II(AC) | ||
Over Voltage Category | DC Type II / AC Type III | ||
Interface | |||
Battery Communication Interface | RS485/CAN | ||
Monitor Mode | RS485/USB/CAN/Wifi/GPRS(optional) | ||
General Data | |||
Operating Temperature Range (°C) | -40 to +60°C, >45°C Derating | ||
Permissible Ambient Humidity | 0-95% | ||
Permissible Altitude | 2000m | ||
Noise (dB) | <30 | ||
Ingress Protection(IP) Rating | IP65 | ||
Inverter Topology | Non-Isolated | ||
Cabinet Size (WxHxD mm) | 450Wx650Hx280D | ||
Weight (kg) | 34 | ||
Type of Cooling | Smart Air Cooling | ||
Warranty | 5 Years (10 Years Optional) | ||
General Data | |||
Grid Certification | VDE4105, IEC61727/62116, VDE0126, AS4777.2, CE10 21, EN50549-1, G98, G99C10-11, UNE217002, NBR16149/NBR16150 | ||
Safety/EMC Standards | IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2 |