Three Phase Hybrid Inverter - 8KW/10KW/12KW
    Publish time 2024-08-29 11:13    
Three Phase Hybrid Inverter - 8KW/10KW/12KW

FEATURES

 

• 100% unbalanced output, each phase; Max. output up to 50% rated power                    

• Up to 2 MPPTs, Max. charging/discharging current up to 240A                          

• Max. 6 pcs parallel                        

• 6 time periods for battery charging/discharging                         

• On-grid and off-grid operation; Support multiple batteries in parallel                      

• AC couple to retrofit existing solar system                  

• IP65 protection grade                  

• Support storing energy from diesel generator


ModelPD0080G-TPM-EUPD0100G-TPM-EUPD0120G-TPM-EU
Battery Input   Data
Battery TypeLead-acid   or Lithium-ion
Battery   Voltage Range (V)40-60V
Max. Charging   Current (A)190A210A240A
Max.   Discharging Current (A)190A210A240A
Charging   Strategy for Li-ion BatterySelf-adaption to BMS
Number of   Battery Input1
PV String   Input Data
Max. PV Input   Power (W)10400W13000W15600W
Max. PV Input   Voltage (V)800V
Start-up   Voltage (V)160V
MPPT Voltage   Range (V)200-650V
Rated PV Input   Voltage (V)550V
Full Load DC   Voltage Range350-650V
Max. Operating   PV Input Current (A)13A + 13A26A + 13A
Max. Input   Short-Circuit Current (A)17A + 17A34A + 17A
No. of MPPT2
No. of Strings   per MPPT1+12+2
AC   Input/Output Data
Rated AC   Input/Output Active Power (W)80001000012000
Max. AC   Input/Output Apparent Power (VA)88001100013200
Peak   Power(off-grid)2 times of rated power, 10s
Rated AC   Input/Output Current (A)12.16/11.615.21/14.518.25/17.4
Max. AC   Input/Output Current (A)13.38/12.816.73/15.920.07/19.1
Max. Three-phase Unbalanced Output Current (A)18.18//17.422.72/21.727.27/26.1
Max. Continuous AC Passthrough (grid to load) (A)45
Max. Output   Short Circuit Current (A)75
Peak Power   (off-grid) (W)2 times of rated power, 10s
Power Factor   Adjustment Range0.8   leading to 0.8 lagging
Output   Frequency and Voltage50/60Hz; 3L+N+PE, 220/380V,   230/400V (three phase)
Grid TypeThree Phase
Total Current   Harmonic Distortion THDi<3% (of nominal power)
DC Injection   Current<0.5% In
Efficiency
Max.   Efficiency97.6%
Euro   Efficiency96.5%
MPPT   Efficiency>99%
Equipment   Protection
IntegratedPV   Arc Fault Detection, PV Input Lightning Protection, Anti-islanding   Protection,
PV String Input Reverse Polarity Protection, Insulation Resistor Detection,  
Residual Current Monitoring Unit, Output Over Current Protection, Output   Shorted Protection
Surge   Protection LevelTYPE II(DC), TYPE II(AC)
Over Voltage   CategoryDC Type II / AC Type III
Interface
Battery   Communication InterfaceRS485/CAN
Monitor ModeRS485/USB/CAN/Wifi/GPRS(optional)
General Data
Operating   Temperature Range (°C)-40 to +60°C, >45°C   Derating
Permissible   Ambient Humidity0-95%
Permissible   Altitude2000m
Noise (dB)<30
Ingress   Protection(IP) RatingIP65
Inverter   TopologyNon-Isolated
Cabinet Size   (WxHxD mm)450Wx650Hx280D
Weight (kg)34
Type of   CoolingSmart Air Cooling
Warranty5 Years (10 Years Optional)
General Data
Grid CertificationVDE4105,   IEC61727/62116, VDE0126, AS4777.2, CE10 21, EN50549-1, G98, G99C10-11,   UNE217002, NBR16149/NBR16150
Safety/EMC StandardsIEC/EN   61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2